Curing
Column Curing
After one day of concreting, formwork was removed from column
and curing agent was applied to concrete surface. Application of curing
compound should be done immediately after striking the formwork and application
done as single coating. Curing membrane film should maintain minimum 4 full
days. (Figure 1.13).
Curing Agent – MASTERKURE 128 – Polymeric
emulsion based concrete curing compound
MASTERKURE 128 is a ready to use, clear membrane curing
compound based on selected polymeric emulsion which when applied on freshly
placed concrete surface provide an efficient curing membrane with excellent non
yellowing properties. This is also offered with fugitive dye as MASTERKURE 128
FD for easier identification of coated area.
Properties
•
Supply form: Liquid
•
Color: White – MASTERKURE 128
: Colored – MASTERKUE 128 FD
•
Coverage: Smooth dense surface – 12 m2/l
: Porous rough surface - 6 m2/l
•
Nontoxic and non-flammable compound
Figure 1.13. Column Curing
Slab Curing
For slab top curing water ponding method was used and
additionally polythene was placed on top of the slab because due to sunny
condition evaporation of water can be happened. (Figure
1.14).
Figure 1.14. Slab Curing